SITRANS FUS060 transmitter
概述
SITRANS FUS060 is a transit time based transmitter designedfor ultrasonic flowmetering with dedicated sensors in the FUSinline series up to DN 500. SITRANS FUS060 is engineeredfor high performance and is suitable for 1- and 2-pathflowmeters.
优势
Superior signal resolution for optimum turn down ratio
Simple menu-based local operation with two-line display and fouroptical input elements, for unlimited use in potentially explosiveatmospheres
Self-monitoring and diagnostic
Operate up to 2 paths
ATEX II G Ex dem [ia/ib] IIC T6/T4/T3Gb
Remote installation up to 120 m from sensor
1 analog output (4 to 20 mA) standard withHART-protocol, 1 digital frequency or pulse output, 1 relay outputfor limit, alarms, flow direction
PROFIBUS PA Profile 2, 1 digital frequency or pulse output
应用
The main application for flowmeters with the transmitterSITRANS FUS060 is measurement volume of water and wastewater.
设计
The transmitter type FUS060 is designed for remote installation innon-hazardous or hazardous areas.
The transmitter is designed for use in a flowmeter system togetherwith sensors type SONOKIT, SONO 3300 and SONO 3100.
The FUS060 is ordered as part of a complete flowmeter system. Itcan be ordered separately as spare part and manually programmedwith the sensor data.
功能
Displays and keypadOperation of the SITRANS FUS060 transmitter can be carried outusing:
Keypad and display unit
HART communicator
PC/laptop and SIMATIC PDM software via HART communication
PC/laptop and SIMATIC PDM software using PROFIBUS PAcommunication
HART communication
PROFIBUS PA communication
The operating and display panel permits simple operation withoutsupplementary equipment. It is not necessary to open the housing.All changes to a setting can therefore also be carried out in thepotentially explosive atmosphere.
Operating and display panel
The individual functions and parameters are selected using ahierarchical, multi-lange input menu and four infrared keys. Theparameters can be specifically selected and modified using codes,e.g.:
Operating parameters such as measuring range, physical dimensions,device information
Limits for flow, totalizer, ultrasonic velocity or ultrasonicamplitude
Noise suppression using damping, error stages and hysteresis
Display parameters (freely-configurable display)
Display in volume or mass dimensions
Density as constant input value for conversion of volume into massdimensions
Forward/backward measurement
Flow direction
Diagnostics functions and control values
Functions of the PROFIBUS PA output:
flow, net quantity (volume or mass), ultrasonic velocity,ultrasonic amplitude, forward quantity (volume or mass), backwardquantity (volume or mass)
Functions of the analog output:
flow, ultrasonic velocity or ultrasonic amplitude
Functions of digital output 1:
pulse output, frequency output, limit, flow direction or devicestatus
Functions of digital output 2:
limit, flow direction or device status
Simulation of output signal via analog output, digital output 1 anddigital output 2
The HART protocol is implemented via the analog output (currentoutput). Using this communication facility, the device can beparameterized with a PC/laptop and SIMATIC PDM software inaddition to local operation.
In the version with PROFIBUS PA, the analog output is replacedby the digital PROFIBUS PA output. The device can then beparameterized via PROFIBUS communication and with SIMATIC PDMin addition to local operation.
集成
The transmitter output is often used as input for an automationsystem or as input for systems of remote reading.
The SITRANS FUS060 transmitter offers current, pulse and relayoutputs as standard output functions and supports HART or ProfibusPA communication.
The settings of the transmitter output functions are individuallyprogrammed via keypad and display menu.